home | about | blog | contact | how to buy | Spare parts | privacy and policy
top-icon top-icon
top-icon
EN
OrdersCustomPartsCatalog
Shipping & pickup
Checking stock…
Enter a 5-digit postcode to see shipping cost and time for this item
Search
HOME / ENGINE AND MOTOR / Electric motor / 220v. electric motor / 

MITSUBISHI SCL-QR 3HP 4P 220V. Single Phase Motor

Brand : MITSUBISHI

MITSUBISHI

MITSUBISHI SCL-QR 3HP 4P 220V. Single Phase Motor

13-SCL-QR3HP

9,590 Baht

MITSUBISHI SKU 13-SCL-QR3HP ⧉
~ Installment 1,042 Baht / month × 10
In stock
Out of stock

Price 9,590 Baht
(VAT included)

Weight : 38.2 kg

Buy via
Reserve via

Ask about restock or get notified via LINE

Brand country
Japan
Weight
38.2 kg

MITSUBISHI SCL-QR 3HP 4P 220V. Single Phase Motor

  • Ships in 1-3 days
  • Same Day · Bangkok area
  • Installment ~1,042 THB/mo
Share
  • SKU 13-SCL-QR3HP
  • Estimated Delivery 1-3 days to ThailandShips
  • Shipping Rate calculated
  • Returns product within 7 days
  • This type of trade cannot cash on delivery.
    Due to weight over 25 kg

Trust Site 100% safe and secure
- You can request a refund immediately.
- Request a refund if the product is not as specified.
- Products sent with track and warranty for every piece

Price {{xAttr.product_price | number : fractionSize }}  THB

Customers Also Viewed

Specifications
Power 3 HP (2.2Kw.)
Power In 220V.
Motor Speed 1450 Rpm.
rated eff 82.3%
Frame 112 m
rating S1
น้ำหนักเฉพาะตัวมอเตอร์ 32.2 kg
น้ำหนักรวมลังไม้ 38.2 kg

   Electric Motors

 มอเตอร์  MITSUBISHI 3 แรงม้า รุ่น SCL-QR3HP  220V.

การใช้งาน มอเตอร์  MITSUBISHI 3 แรงม้า

First-time Use

1. The motor shaft must be able to rotate smoothly by hand without jamming.

2. Check that properly sized fuses are installed.

3. Make sure power and ground wires are connected

4. Check that the motor rotation direction matches the driven machine.

5. Check that the coupling to the machine is tight and sufficiently secure.

Electric Motors

General Use

1. Minimize the load during startup, then gradually increase the load once the motor reaches full speed

2.ตรวจวัดกระแสในขณะทำงานว่าเกินกว่าที่ระบุไว้ในป้ายสินค้าหรือไม่หากเกินให้ปรับลดโหลดลง มิฉะนั้นอาจทำให้ขดลวดมอเตอร์ไหม้ได้

3. Check that there is no abnormal noise in the bearings

4.หากเกิดไฟดับ ให้ทำการสับสวิตช์ตัดไฟ เพื่อป้องกันมอเตอรืโอเวอร์โหลดหรืออันตรายอื่นๆ เนื่องจากมอเตอร์รับโหลดกะทันหันเมื่อไฟมา

5. Stop the motor immediately if any abnormality occurs

Inspection and Maintenance Interval

1. Infrequently used motors accumulate moisture from long downtimes, making daily inspections crucial.

On the other hand, disassembly inspection does not need to be performed frequently.

2. Continuously operating motors, such as pumps and fans, should be regularly disassembled for inspection.

3. Record results of daily, monthly, and disassembly inspections.

For reference and planning future maintenance.

4. Schedule and perform disassembly inspections based on usage

If installed in a dusty area with low usage, inspect every 1-2 years; if used continuously, inspect every year.

If installed in a clean area with light use, inspect every 2–3 years; for continuous use, inspect every 1–3 years.

Abnormal Symptoms

Motor does not work

Possible Causes                                     Solution

1. No electrical power | 1. Check the electrical system.

2. Blown fuse 2. Replace the fuse

3. Broken/cracked wiring | 3. Replace wiring.

4. Poor power supply connection | 4. Clean connection points / tighten securely.

5. Low voltage | 5. Check electrical system or adjust wire gauge/length.

Solution

Abnormal motor noise

Possible Causes / Solutions

1. Missing 1 phase (for 3-phase motors) | 1. Inspect switches and control circuits.

2. Abnormal power supply 2. Inspect and fix the power supply

3. Overload | 3. Select a motor with suitable power rating.

4. Damaged bearing 4. Replace with a new bearing

5. Low or degraded grease in bearings (open bearings) 5. Regrease or replace with new bearings

Motor runs slowly

Possible Causes                                           Solution

1. Starter system malfunction | 1. Inspect and repair the starter system.

2. Abnormal power supply 2. Inspect and fix the power supply

3. Overload | 3. Select a motor with suitable power rating.

Abnormally high vibration

Possible Causes / Solutions

1. Connected machine excessively unbalanced: 1. Check and correct the balance of the assembled machine components

2. Coupling misalignment: 2. Realign accurately (consider thermal expansion as well)

3. Unstable motor base or loose mounting bolts: 3. Reinforce the base or tighten the bolts securely

Electric Motors

Customers Also Purchased

How to buy

1
Register by login or fill out via website
2
Click on the button to enter the basket and click the button.Pay on the right hand, follow 3 steps
3
Wait for the confirmation email and receive the sms. The tracking number of the shipping you selected via sms
4
Before sending the product, there will be staff to go to the mark you specified again.

Product rating


  {{five_star}}
  {{four_star}}
  {{three_star}}
  {{two_star}}
  {{one_star}}

Your review

Reviews products

{{comment.nickname}} says:

{{comment.comment_content}}
{{comment.date_comment}}