home | about | blog | contact | how to buy | Spare parts | privacy and policy
top-icon top-icon
top-icon
EN
OrdersCustomPartsCatalog
Shipping & pickup
Checking stock…
Enter a 5-digit postcode to see shipping cost and time for this item
Search
MITSUBISHI IP-505R2 Inverter Automatic Water Pump 500W

13-ip505r2

17,480 Baht

MITSUBISHI SKU 13-ip505r2 ⧉
~ Installment 1,898 Baht / month × 10
In stock
Out of stock

Price 17,480 Baht
(VAT included)

Weight : 12.0 kg

Buy via
Reserve via

Ask about restock or get notified via LINE

Brand country
Japan
Weight
12.0 kg

500-watt inverter automatic water pump delivers consistently strong water pressure throughout the entire house even when multiple points are used simultaneously. Maximum energy savings with smart Inverter technology, quiet operation, durable build, and premium safety standards.

  • Ships in 1-3 days
  • Same Day · Bangkok area
  • Installment ~1,898 THB/mo
Share
  • SKU 13-ip505r2
  • Estimated Delivery 1-3 days to ThailandShips
  • Shipping Rate calculated
  • Returns product within 7 days
  • Cash on delivery

Trust Site 100% safe and secure
- You can request a refund immediately.
- Request a refund if the product is not as specified.
- Products sent with track and warranty for every piece

Price {{xAttr.product_price | number : fractionSize }}  THB

Customers Also Viewed

Specifications
Motor (W) 500
Suction Lift (m) 8 (Low) / 2 (High)
Discharge head (m) 23 (Low) / 26 (High)
Max. Flow Rate (L/min) 73
ท่อดูด มม. (นิ้ว) 35 (1-1/4)
ท่อจ่าย มม. (นิ้ว) 35 (1-1/4)
size (Width x Deep x High) (mm) 380 x 320 x 340
จำนวนจุดที่ใช้น้ำ 1-12

Inverter Automatic Water Pump MITSUBISHI IP-505R2 Power 500 Watts
The Mitsubishi IP-505R2 is the ideal solution for water management in large homes. Featuring an Inverter Control system that regulates the motor speed according to actual water usage, it maintains constant water pressure at all times—whether showering, running the washing machine, or watering plants simultaneously. It features a modern, space-saving design and sealed motor technology that reduces noise and extends operational lifespan.


Features
- Inverter Control: Adjusts motor speed according to actual water usage, ensuring stable water pressure and energy savings
- DCBL Motor: Brushless DC motor with innovative resin-sealed structure, protects against water and insects, operates ultra-quietly
- Nitrogen Pressure Tank: Pressure tank charged with nitrogen gas and a rubber diaphragm, providing stable pressure with no gas refills needed throughout its service life
- Safety First: Over/under voltage protection, dry run protection, and made with flame-retardant materials
- Anti-Rust: Pump head assembly made of a special copper alloy, durable and rust-free


Applications
Suitable for large houses or home offices (2-3 stories)
Supports simultaneous water usage for up to 10-12 points
Suitable for devices requiring constant water pressure, such as water heaters, rain showers, or bathroom body massage jet systems


Specifications
- Model: IP-505R2
- Motor Power: 500 W
- Suction Head: 8 m
- Discharge Head: 23 m
- Maximum Flow Rate: 73 L/min
- Flow Rate at 12 m Head: 61 L/min
- Suction/Discharge Pipe Size: 35 mm (1-1/4 in.)
- Control System: Inverter Control


Basic troubleshooting for abnormal issues in square-tank water pumps 

1. Mitsubishi square-tank water pump makes abnormal noise: Noise can stem from various causes, but most commonly includes: 
- The cooling fan is deteriorated, cracked, or broken, or insects got inside causing unusual noises. Solution: Use a Phillips screwdriver and snap ring pliers. Unscrew the fan cover using the Phillips screwdriver, use the snap ring pliers to remove the retaining ring on the fan, pull the old fan out, insert the new fan, and reassemble as before. 
- Stones, sediment, or gravel slipped inside the water impeller. Solution: Use an 8 mm socket wrench or T-handle socket wrench to unscrew and open the impeller cover, taking care not to tear or damage the front pump gasket, then thoroughly clean and remove all foreign objects and reassemble as before. 
- Bearings are damaged or deteriorated. Symptoms include continuous loud noise during operation. This could be caused by rust from a deteriorated shaft seal allowing water into the bearing, or bearing failure due to wear and tear. Solution: Must be performed by a professional technician; it is recommended to contact a nearby technician for an inspection. 

2. Mitsubishi constant-pressure square-tank water pump does not run
A water pump not operating can also stem from several causes, but the most common ones encountered are as follows:
- The Mitsubishi water pump does not run due to excessive temperature: current pump models feature a thermal cut-off system to prevent the motor from burning out. Solution: Stop operating the water pump, switch off the circuit breaker, wait for the motor to cool down, and then turn it back on.
- The Mitsubishi water pump does not run due to a stuck or deteriorated pressure switch. Solution: Switch off the circuit breaker, use a Phillips screwdriver to open the cover and remove the pressure switch, then press it to check if it functions normally, or it may need to be replaced with a new pressure switch. 
- The Mitsubishi water pump does not run due to a lack of power supply, which may be caused by a broken power cord or no power from the source at all. How to check: Use a test pen to check at the circuit breaker, or remove the machine cover and the condenser cover using a Phillips screwdriver, then use a test pen to check for electric current. 
- The Mitsubishi water pump does not run due to a damaged or degraded condenser/capacitor. Solution: Turn off the circuit breaker, remove the machine cover and capacitor cover, and inspect the capacitor for swelling or short-circuiting; resolve the issue by replacing it with a new capacitor. 
- The Mitsubishi water pump does not run due to motor damage or short-circuiting, which is quite rare but can happen if the water pump is overloaded or worn out over a long service life. How to check or fix: This may require technical expertise; it is recommended to call a technician for inspection. 

3. Mitsubishi water pump surges/cycles intermittently
The water pump surges or cycles on and off rapidly, which may be caused by a water leak at the pump or within the household plumbing system. How to check: Close the outlet water valve and observe whether the surging stops. If it stops, this indicates a leak in the home's plumbing system, such as a dripping tap or a faucet that is not completely closed. If the surging does not stop after closing the outlet valve, it may be caused by a leak at the pump itself, such as a cracked body/casing, or deteriorated shaft seals or pump face seals; resolve according to the specific issue by replacing the damaged parts. 


Water Pump Maintenance Guide 
1. Observe the operation of the water pump, such as whether the water pressure is normal, the sound is normal, and the pump switches on and off properly.
2. Open the cover periodically to check inside for any leaks.
3. Prevent any water leaks inside the house; leaving leaks unattended for a long time will cause the pump to work harder and more frequently, overloading the motor unnecessarily and increasing electricity costs.
4. Always close the faucet completely immediately after using water.
5. Check the cleanliness of the water in the storage tank to prevent rocks, dirt, and sand from entering the pump.
6. Build a roof to shield it from sun and rain for a longer service life.


Inverter Automatic Water Pump MITSUBISHI IP 505R2 Power 500 W


The water pump should be installed as a dual system (2-way system).

- Prepare the area for placing the water tank and the pump; there should be a roof to protect against sun and rain for a longer service life.
- Place the water pump as close to the water tank as possible for maximum efficiency.
- Connect the pipe from the water meter by first shutting off the meter valve, then connect a tee fitting to split the flow into the water tank and directly into the house.
- Run the pipe into the water tank, installing 1 ball valve to shut off the water for maintenance, and properly install the float valve inside the water tank.
- Screw straight threaded adapters into the tank's water outlet and the pump, wrapping Teflon tape clockwise around the threads about 10–15 turns. 
- Connect the pipe to the ball valve properly, then connect the pipe from the water tank to the water pump, with the ball valve installed between the tank and the pump.
- Then connect the water outlet pipe with another ball valve, followed by a tee fitting connecting to the house and the municipal water supply
- Run a pipe from the meter and tank tee to connect to the tee in front of the water pump, with 1 check valve installed in between to prevent backflow when water is drawn from the water pump. 
- Connect the electrical wiring to the water pump while keeping the circuit breaker turned off.
- Open the water valves at the meter and at the tank inlet; wait until the water tank is completely full.
- Open the valve from the water tank to the pump while keeping the outlet valve closed.
- Turn on the water pump's circuit breaker, then wait a moment for the pump to run and then stop. 
- Open the outlet valve into the house, then check by  14 turning the indoor faucets on and off to verify the pump's operation. That completes the installation.

Customers Also Purchased

How to buy

1
Register by login or fill out via website
2
Click on the button to enter the basket and click the button.Pay on the right hand, follow 3 steps
3
Wait for the confirmation email and receive the sms. The tracking number of the shipping you selected via sms
4
Before sending the product, there will be staff to go to the mark you specified again.

Product rating


  {{five_star}}
  {{four_star}}
  {{three_star}}
  {{two_star}}
  {{one_star}}

Your review

Reviews products

{{comment.nickname}} says:

{{comment.comment_content}}
{{comment.date_comment}}